Z‐wave configuration parameters, Functions parameter number parameter value range – Remotec ZTS-110 V3.14 User Manual
Page 35

35
Z‐Wave Configuration Parameters
Different user has different preferred settings of their thermostat, you may use the below configuration
parameters to change settings of corresponding functionality.
Functions
Parameter Number Parameter value range
Swing
1 (0x01)
1 (0x01) = 1
o
F / 0.5
o
C
2 (0x02) = 2
o
F / 1.0
o
C (default)
3 (0x03) = 3
o
F / 1.5
o
C
4 (0x04) = 4
o
F / 2.0
o
C
Differential
2 (0x02)
1 (0x01) = 1
o
F / 0.5
o
C
2 (0x02) = 2
o
F / 1.0
o
C (default)
3 (0x03) = 3
o
F / 1.5
o
C
4 (0x04) = 4
o
F / 2.0
o
C
Set filter counter
3 (0x03)
500 (0x01F4) to 4000 (0x0FA0) hours
Default = 500 (0x01F4) hours
Resolution = 100 (0x0064) hours
Report filter counter
(read only)
4 (0x04)
0 (0x0000) to 9999 (0x270F) hours
Scale of temperature
5 (0x05)
0 (0x00) =
o
C
1 (0x01) =
o
F (default)
Dead band
(On thermostats that
automatically control both
heating and cooling systems, a
dead band is a temperature
range in which neither system
turns on. The dead band
prevents the thermostat from
activating heat and cooling in
rapid succession. This
conserves energy by providing
a range of temperatures
requiring no energy
consumption)
14(0x0E)
Dead band value:
3(0x03)= 3
o
F/ 1.5
o
C
4(0x04)= 4
o
F/ 2.0
o
C (default)
5(0x05)= 5
o
F/ 2.5
o
C
6(0x06)= 6
o
F/ 3.0
o
C