Short cycle start up protection, System output – Remotec ZTS-110 V3.14 User Manual
Page 28

28
3
Press and hold “Mode” key to set
the alert time for the filter usage.
“Target” icon will be shown on
screen and flashing.
Press “UP” or “Down” to set the
alert time.
(Range from 500 to 4000 Hours
Step size is 100hrs)
Press “Prog” key to confirm the
setting and go back to filter
counter page.
Press “Home" key once to go
back to the Home page.
4
FILTER icon will be shown on the
screen at Home page when the
usage hours were reached to set
time.
Short Cycle Start Up Protection
To protect the compressor / Heat pump, those outputs forced off until 3minutes count down
finished. Those outputs can be activated according to the room temperature after 3 minutes.
System
Output
Non Heat pump system
Compressor
Heat pump system
1st stage heat and compressor