Hydraulic diagram for heat pump assembly WKF Düsseldorf 2
Functions: heating or cooling and hot water, operating mode: monoenergetic.
Only one cycle is possible for cooling; active cooling or floor heating (passive cooling)!
A
B
C
FB
KK
KW
WW
ZK
AB
B
A
S08
B
AB
A
EFS
Fig. 72: Example hydraulic diagram for HP assembly WKF Düsseldorf 2
A:
Outdoor unit
B:
WFK indoor unit
C:
Storage tank
FB:
Floor heating cycle
KK:
Cooling cycle
KW:
Cold water
WW:
Hot water
ZK:
Circulation
Menu item
Parameter
Factory setting
Control panel address
Control panel 1-3
Control panel 1
Country
Deutschland - Slovensko
Deutschland
Load setting
Accept the parameters
Saving process
Language
Deutsch - Polski
Deutsch
Time zone
Var. time zones possible
Winter + 1(CET) (for Europe)
Date setting
Year / Month / Day
Current date setting
Time setting
Hours / Minutes
Current time setting
Activate heat pump
Activated / Deactivated
Activated
Operating mode
Monoenergetic / Bivalent
alternative
Monoenergetic / Enable as required
Domestic water heating
Activated / Deactivated
Activated
Storage tank set temperature
"40°C - 65°C"
45°C
Hot water circulation
Activated / Deactivated
Deactivated
Circulation type
Impulse or Temperature
Impulse