Remko smart wp manager – REMKO WPM-Smart-Control-Manual for specialists-WKF-085 User Manual
Page 26

Activating the heat pump
The controller detects automatically that a heat
pump has been connected. If necessary, activate
the heat pump (select with the rotary knob and
confirm with "OK").
Fig. 36: Activating the heat pump
Menu item
Parameter
Factory setting
Activating
the heat
pump
Activated
Activated
Deactivated
Press "Next".
Selecting the operating mode
Fig. 37: Bivalent alternative operating mode
Fig. 38: Monoenergetic operating mode
Menu item
Parameter
Factory setting
Operating
mode selec-
tion
Monoenergetic
Monoenergetic
Bivalent alterna-
tive
Selection of the auxiliary heat generator:
- Bivalent alternative (heat pump or oil/gas-fired
boiler)
- Monoenergetic (heat pump and/or Smart Serv
electric heating element) according to usable limits
Domestic water heating
Optionally, you can activate or deactivate the
"Domestic water heating" function. Activate
domestic water heating if domestic water has to be
heated for washing or showering (select with the
rotary knob and confirm with "OK"). When this
function is activated, the associated parameters
are then queried. Pay attention to information on
the display.
Fig. 39: Domestic water heating
Press "Next".
REMKO Smart WP MANAGER
26