Remko smart wp manager – REMKO WPM-Smart-Control-Manual for specialists-WKF-085 User Manual
Page 44

Menu item
Parameter
Factory setting
Circulation running time
1 min - 15 mins
5 mins
Disable switch-on
1 min - 15 mins
5 mins
Circulation type
Impulse or Temperature
Temperature
Circulation set temp.
"25°C - 65°C"
35°C
Area-heating heating cycle
Activated / Deactivated
Following, as required
Area-heating heating cycle
Deactivated
No other parameters
Area-heating heating cycle
Deactivated
Parameter as required
Heating cycle mode
Heating curve / Fixed value
Heating curve
Heating-curve base point
"15°C - 25°C"
20°C (or according to design)
Standard inlet temperature
"28°C - 90°C"
35°C (or according to design)
Standard outside temperature "0°C - 20°C"
According to design or locale
Heating cycle radiators
Activated / Deactivated
As required
Heating cycle radiators
Activated
Following parameters, as required
Heating cycle mode
Heating curve / Fixed value
Heating curve
Heating-curve base point
"15°C - 35°C"
20°C (or according to design)
Standard inlet temperature
"40°C - 90°C"
45°C (or according to design)
Standard outside temperature "0°C - 20°C"
According to design or locale
Building time constant
"0 h - 100 h"
10 h
Standard heating load
"0 kW - 25 kW"
According to design or heating load calcu-
lation
Cooling function
Activated / Deactivated
Deactivated / Enable as required
Separate cooling cycle
Activated / Deactivated
Deactivated / Enable as required
Solar plant
Activated / Deactivated
Deactivated / Enable as required
Solar plant
Activated
Following parameters, as required
Pump type
Asynchronous
Following parameters, as required
Asynchronous speed control
system
On / Off
As required
Pump type
EC pump
(high-efficiency pump)
As required
Solar speed control system
Activated / Deactivated
As required
Solar HM
Deactivated
As required
Manual medium flow rate
2 l/min - 30 l/min
Manual medium flow rate 5.0 l/min
Medium flow rate probe
0 ml / lmp - 10 ml / lmp
5.7 ml / lmp
Heat carrier medium
As required
Tyfocor-L
Solar set temperature
"5°C - 95°C"
85°C
Solar heating
Activated / Deactivated
Deactivated / Enable as required
REMKO Smart WP MANAGER