REMKO WPM-Smart-Control-Manual for specialists-WKF-085 User Manual
Page 35

Menu item
Parameter
Factory setting
Pump type
(solar cycle)
Asynchronous
pump
EC pump
Selection
according to
pump type
installed in the
solar cycle
Solar speed control system
Activate if you want the solar pump to modulate
according to solar capacity
Activation of the speed control system for the
pump in the solar cycle: the pump can be activated
according to demand, for efficiency reasons; as
solar radiation increases, the speed of the pump
increases.
When using a pump which is not suitable for the
speed control system, the system should be deac-
tivated.
(We recommend use of a speed-controlled pump).
Fig. 61: Activating the speed control system
Menu item
Parameter
Factory setting
Solar speed
control
system
Deactivated
Deactivated
Activated
Menu item
Parameter
Factory setting
Asynchro-
nous speed
control
system
On
On
Off
Medium flow rate probe
The amount of heat delivered from solar yields is
recorded continuously, and can be called up in the
form of a daily or cumulative value.
If no medium flow rate probe is installed, a manual
medium flow rate can be selected. The heat meter
can also be deactivated, if desired.
Fig. 62: Selecting the medium flow rate probe
Menu item
Parameter
Factory setting
Solar HM
Deactivated
Setting with
heat meter
installed
Manual medium
flow rate
Medium flow
rate probe
Press "Next".
35