Cooling function
Activate (select with the rotary knob and confirm
with "OK") if the building is to be actively cooled
with the heat pump in summer.
Please ensure that the cycle being used for the
cooling function is designed for this purpose.
Fig. 57: Activating the cooling function
Menu item
Parameter
Factory setting
Cooling
function
Deactivated
Deactivated
Activated
Press "Next".
Separate cooling cycle
Activate (select with the rotary knob and confirm
with "OK") if a separate cycle is installed which is
used solely for the cooling function (e.g. with fan
convectors).
Fig. 58: Activating the separate cooling cycle
Menu item
Parameter
Factory setting
Separate
cooling cycle
Deactivated
Deactivated
Activated
Press "Next".
Solar plant
Deactivate (turn the rotary knob to the left and con-
firm with "OK") if no solar plant is installed. It can
be activated again at a later date.
Activate (turn the rotary knob to the right and con-
firm with "OK") if a solar plant is installed.
Fig. 59: Activating the solar plant
Menu item
Parameter
Factory setting
Solar plant
Deactivated
Deactivated
Activated
Selecting the pump system
Select the pump system for the speed control
system (select with the rotary knob and confirm
with "OK"). The speed control system is available
for a solar cycle with asynchronous pump (con-
trolled by an A10 with "wave packets"), as well as
for one or two solar cycles with high-efficiency
pump (controlled by an A40/A41 with "PWM").
We recommend activating an EC pump. The solar
pump adapts automatically to solar capacity. If the
temperature difference increases due to increased
solar capacity, the speed of the solar pump is
increased. (This results in a higher degree of effi-
ciency of the solar plant as well as lower power
consumption of the solar pump).
Fig. 60: Selecting the pump system