REMKO WPM-Smart-Control-Manual for specialists-WKF-085 User Manual
Page 39

Menu item
Parameter
Factory setting
Control panel address
Control panel 1-3
Control panel 1
Country
Deutschland - Slovensko
Deutschland
Load setting
Accept the parameters
Saving process
Language
Deutsch - Polski
Deutsch
Time zone
Var. time zones possible
Winter + 1(CET) (for Europe)
Date setting
Year / Month / Day
Current date setting
Time setting
Hours / Minutes
Current time setting
Activate heat pump
Activated / Deactivated
Activated
Operating mode
Monoenergetic / Bivalent
alternative
Monoenergetic / Enable as required
Domestic water heating
Activated / Deactivated
Activated
Storage tank set temperature
"40°C - 65°C"
45°C
Hot water circulation
Activated / Deactivated
Deactivated
Circulation type
Impulse or Temperature
Impulse
Circulation running time
1 min - 15 mins
5 mins
Disable switch-on
1 min - 15 mins
5 mins
Circulation type
Impulse or Temperature
Temperature
Circulation set temp.
"25°C - 65°C"
35°C
Area-heating heating cycle
Activated / Deactivated
Following, as required
Area-heating heating cycle
Deactivated
No other parameters
Area-heating heating cycle
Deactivated
Parameter as required
Heating cycle mode
Heating curve / Fixed value
Heating curve
Heating-curve base point
"15°C - 25°C"
20°C (or according to design)
Standard inlet temperature
"28°C - 90°C"
35°C (or according to design)
Standard outside temperature "0°C - 20°C"
According to design or locale
Standard inlet temperature
"28°C - 90°C"
35°C (or according to design)
Standard outside temperature "0°C - 20°C"
According to design or locale
Heating cycle radiators
Activated / Deactivated
As required
Heating cycle radiators
Activated
Following parameters, as required
Heating cycle mode
Heating curve / Fixed value
Heating curve
Heating-curve base point
"15°C - 35°C"
20°C (or according to design)
Standard inlet temperature
"40°C - 90°C"
45°C (or according to design)
Standard outside temperature "0°C - 20°C"
According to design or locale
Building time constant
"0 h - 100 h"
10 h
Standard heating load
"0 kW - 25 kW"
According to design or heating load calcu-
lation
39