Manual operation
The unit can be manually operated if, for example, the
infrared remote control is not functioning properly or
has been lost.
Open the air inlet grille of the indoor unit and press the
button on the right side.
The following operating modes are then activated:

MODE =

Automatic

(Operating cycle of the compressor

On → 20 min. Off → 10 min.)

TEMP. =

24°C, FAN = Automatic

SWING =

On,

TIMER

= Off.

Shutting Down the Unit


Temporary shutdown

1. Let the unit run in cool mode for 30 minutes at a

temperature setting of 31°C.

2. Switch the indoor unit off using the remote control.
3. Disconnect the system with the main switch or fuse

protection from the power supply.

4. Check the indoor unit for visible damage.
5. Clean the indoor unit as described in the

“Maintenance and Service” section.

6. If possible, cover the outdoor unit with a plastic

sheet to protect it from weather conditions.

Permanent shutdown

For environmental safety reasons, the air conditioners
may only be disassembled by authorised service cen-
tres.

Manual air distribution
There are individually adjustable air directing plate fins
on the air outlet side for horizontally distributing the air.
Set the air directing plate fins in the desired position
with the left and right adjustment levers.

*

Never adjust the fins when the unit is in automatic
swing mode! Do not reach into the unit!
There is a risk of injuring your hand on the fan
motor.

LED display on the indoor unit

POWER

On / Off

(red)

PROTECT Compressor protection (green)
RUN Compressor

mode

(green)

TIMER Timer

mode

(yellow)

Display

Room temperature / target temperature

error

code

The display changes to the target temperature display
when the settings are made with the remote control.

Left adjustment
lever

Right adjustment
lever

Cause

E3 RUN and TIMER LEDs blink alternately.

Unit switches off after approx. 30 seconds.

Fan motor

E5 TIMER LED blinks.

Room air sensor

E6 RUN LED blinks.

Frost protection
sensor

E9 The LEDs blink alternately for 20 minutes.

Unit switches off after another 20 minutes.

Insufficient refriger-
ant

LED error code

First, remedy the cause of the problem and then reset
the error code display by switching the unit off and off.

Malfunction display

1

Indoor unit ML ...-IT

2

Outdoor unit ML ...-AT

3 Infrared

remote

control

4

Refrigerant

pipes

5

Air inlet grille

6

Air outlet fin with swing motor

7

Manual air directing plate fin
(covered)

System Structure

11

3

4

7

8

9

Outside

Inside

2

1

14

12

10

13

6

15

5

8 Display
9 Receiver
10 Manual mode switch
11 Condenser

fan

12 Wall

lead-through

13 Shut-off

valve

14 Condensation connection ML ...-IT
15 Air