The heat exchanger cools the air below its dew-point due to the low inlet
temperature - this results in the airborne humidity being condensed out.
The "DRY" mode thus dehumidifies the room. After pressing the "DRY"
key the desired temperature and fin position can be selected. The fan is
switched off at certain intervals to lower the fin temperature.
Activate and deactivate your air conditioning unit with the "ON/OFF"
key. The programmed settings and adjustment values from before
the unit was turned off will appear on the display.
DRY mode
DEHUMIDIFICATION
MODE
MODE
q
TMP
or
p
TMP
HEAT mode
HEATING MODE
MODE
q
TMP
or
p
TMP
In the "HEAT" mode you can heat the room (only with cooling / heating
systems with warm operating medium). Actuate the "HEAT" key. Note
that the desired temperature must be higher than the room temperature!
If the set temperature is exceeded by 1 °C, then the controller turns the
heater function off. The COMP. indicator goes out. If the room temperature
drops below the set temperature then the heating function switches back
on again after 3 min. waiting time (COMP indicator flashes).
ON / OFF key
FAN key
After actuating the "FAN" key, "AUTO" can be seen in the fan speed
display. Each further actuation of the key results in a reduction in speed.
ON / OFF
ON / OFF
FAN
FAN
FAN
9