PT-Link II LON

®

Technical Guide

PT-Link II Interface

38

VCB-X PT-Link II LON

®

Property Identifi er:

The PT-Link II LON

®

Link amends the following property identity to

the LON

®

property identifi er.

LONPropertyIdentifi er :

VcbxUnitMode ::= ENUMERATED {

Unoccupied

(0)

Occupied

(1),

Override

Mode

(2),

Holiday

Unoccupied

(3),

Holiday

Occupied

(4),

Forced

Occupied

(5),

Forced

Unoccupied

(6),

}

VcbxControlStatusBits ::= ENUMERATED {

Off

(0),

Vent

Mode

(1),

Cooling

Mode

(2),

Heating

Mode

(3),

Vent

RH

Mode (4),

Cooling

RH

Mode

(5),

Heating

RH

Mode

(6),

Warm

Up

Mode

(7),

Defrost

Mode

(8),

Purge

Mode

(9),

Cool

Down

Mode

(10),

Remote

Cooling

Mode

(11),

Remote

Heating

Mode

(12),

Remote

Vent

Dehum

(13),

Remote

Cool

Dehum

(14),

Remote

Heat

Dehum

(15)

}

VcbxAlarmGroup1Bits ::= BIT STRING {

Bad

Supply

Air

Sensor

(0),

Bad

Return

Air

Sensor

(1),

Bad

Outside

Air

Sensor

(2),

Bad

Space

Sensor

(3),

Bad Main Expansion Board

(4),

Bad

Coil

Temp

Sensor

(5),

Bad

Co2

Sensor

(6),

Bad

Discharge

Sensor

(7),

Bad

OA

CFM

Sensor

(8),

Bad Exhaust CFM Sensor

(9),

Bad Supply CFM Sensor

(10),

Bad

Return

CFM

Sensor

(11),

Bad

Reheat

Module (12),

Bad

ModGas

Module

(13),

Bad Relay Expansion Module

(14),

Missing EM2 Expansion Board

(15)

}

VcbxAlarmGroup2Bits ::= BIT STRING {

Mechanical Cooling Failure

(0),

Mechanical

Heating

Failure

(1),

Fan

Proving

Alarm

(2),

Dirty

Filter

Alarm

(3),

Emergency

Shutdown

Alarm

(4),

Economizer Air Temperature Failure

(5),

Not Economizing When It Should

(6),

Economizing When It Should Not

(7),

Economizer Damper Failure

(8),

Economizer Excess Outdoor Air

(9)

}

VcbxAlarmGroup3Bits ::= BIT STRING {

High Supply Air Cutoff

(0),

Low

Supply

Air

Cutoff

(1),

High Control Mode Signal Alarm

(2),

Low Control Mode Signal Alarm

(3),

Digital Compressor Cutoff Alarm

(4),

Digital Compressor Lockout Alarm

(5),

High

Head

Pressure (6),

Loop Water Proof of Flow

(7),

Low

Suction

Pressure

(8),

Unsafe Suction Pressure

(9),

Low

Leaving

Water

Temp

(10)

}

VcbxOnBoardRelaysBits ::= BIT STRING {

On

Board

Relay

1

(0),

On

Board

Relay

2

(1),

On

Board

Relay

3

(2),

On

Board

Relay

4

(3),

On

Board

Relay

5

(4)

On

Board

Relay

6

(5)

}

Appendix C - VCB-X LON Parameters

Revised 7/10/14