beautypg.com

Maintenance, Troubleshooting, Gas control valve – Montigo ME34-DV2 User Manual

Page 17: Pilot burner adjustment

background image

Page 1

Part No. XG0105B

ME34-DV-2 Homefire

Maintenance

Troubleshooting

If your fireplace still does not operate correctly, consult your dealer or
the manufacturer.
All service and repairs should be performed by a qualified
agency.
All spare parts, optional fans (see optional fan instruction guide), and
optional trim finishes are available from the manufacturer or your local
dealer.

HONEYWELL SV 9500 /SV9600

Troubleshooting Sequence

NOTE:

Before Troubleshooting, Familiarize Yourself With

The Startup And Checkout Procedure.

· TurnGasSupplyoff
· Setthermostatto

call forheat

SV9500/SV9600
ispowered
(24VACnominal)

NO

NO

NO

NO

NO

YES

YES

YES

YES

YES

YES

YES

NO

NO

NO

START

Igniterwarmsup
andglowsred.

PilotValveopens.

Turngason.
PilotBurnerlights?

MainValveopens?

SYSTEMOK

UnplugPilotBurnerCable,
MeasureVoltageat
SV9500/SV9600HSI
Terminals(24VAC
Nominal, SeeINSET)

ReplaceIgniter/
FlameRodAssembly.

ReplaceIgniter/
FlameRodAssembly.

ReplaceSV9500/SV9600

MeasureVoltagetoSV9500
/SV9600. Voltagemust
beatleast19.5VAC

DiscardoldIgniter/
FlameRodAssembly.

ReplaceIgniter/Flame
RodAssemblyandretain.
RestartTroubleshooting
Sequence. Doesmain
valveopen?

Replace
SV9500/
SV9600

Check
Transformer
LineVolt
Supply

Replace
SV9500/
SV9600.
Saveold
Igniter/Flame
RodAssembly
forservice.

INSET

HSI

Terminals

CHECK:

· Linevoltagepower

· Lowvoltage transformer

· LimitController

· Thermostat

· Wiring

· Airprovingswitchon

combustionairblowersystem

· Ventdamper(ifused) isopen

andendswitchmade

Gas Control Valve

Figure 28.

Sit Nova 820 gas valve.

Pilot Burner Adjustment

1. Locate Pilot Adjustment Screw.

(See figure 28.)

2. Adjust pilot screw to provide properly sized flame as shown in

figure 29).

3. After installing or servicing, leak test with a soap solution with

main burner on. Coat pipe and tubing joints, gasket etc. with soap
solution. Bubbles indicate leaks. Tighten any areas where the
bubbles appear until the bubbling stops completely.

ME34-DV-I-2

Figure 29.

Pilot Burner

Troubleshooting

The following is a troubleshooting chart of possible problems:

PROBLEM

CORRECTIVE ACTION

Noisy Pilot Flame

Locate pilot adjustement screw on gas
control valve. Flame is decreased by
turning adjustment screw clockwise.

Pilot won’t ignite

Disconnect remote wires and try to
light pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram

figure

28.

Main burner will

1. Check wiring (

see figure 28).

not light

2. Check wall switch for proper con-
nection.

ME34-DV-2

Manifold Pressure
Test Connection

Pilot Adjustment Screw

Inlet
Pressure

Power
Generator

Wall Switch