Finishing Around the Fireplace

Combustible mantels and mouldings may be safely installed over the
top and on the front of the fireplace provided that they do not project
beyond shaded area shown in Figure 21a. Side wall clearances are

3". Combustible surrounds may be installed with 3" clearance to the
side of the fireplace as shown in Figure 21b.

Fireplace Facing

When selecting the finish material for your fireplace, it is important
to remember the following: HORIZONTAL TRIMS MUST NOT BE
OBSTRUCTED IN ANY WAY - to do so restricts the air supply for
the control compartments and heat exchanger it also prevents
access for servicing controls.
The face of the fireplace may be painted to match the room decor,
provided you use a heat-resistant paint. Decorative facing must not
extend past the fireplace opening at all, because it will interfere with
the access to retainers for removal of glass door.

Installation

elevated mantel temperatures which may be in excess of product
design, for example: candles, plastic or pictures. This can cause
melting, deformation, discoloration or premature failure of T.V. and
radio components.

Painting:

Sheetrock/

Drywall

Header

3

45°

Special care is recommended by the Master Painters and Decorators
Association, when painting the fireplace surrounds, to select and ap-
ply a quality

Alkyd sealer prior to the applying of latex paints. This is

to prevent leaching of water from evaporation and causing a brownish
staining effect to paint over coats.

Top of fireplace

Combustible Facing

Combustible construction

allowed in shaded area.

1

2

3

4

5

6

7

8

9

10

11

12

Figure 21a.

Combustible mantles and facings.

Mantels & Surrounds

NOTE: National Canadian Gas Association mantel test requirements

are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above nor-
mal room temperature and walls above fireplace may be hot to touch.
We recommend careful consideration be given to the effects of

Figure 21b.

Combustible surrounds.

Wiring

Gas Control and Pilot Wiring

ME34-DV-I-2

Figure 22.

Wiring for the ME34-DV-I-2 with Honeywell gas control

and pilot.

Honeywell (Q3450)
Pilot Assembly

Pilot Electrical

Harness Connector

Honeywell Gas

Control (SV9501M)

Gas Control

Connector

Fuse

Limit

Switch

Wall

Switch

Fan Plug

Receptacle

Junction Box

Junction Box Cover

White

Black

Green

40 VA

Transformer

115VAC

24VAC

Grnd Screw

min 8"