beautypg.com

Maintenance, Operation, General – Montigo ME34-DV2 User Manual

Page 16: Lighting instructions, Cleaning, Adjusting the burner

background image

Page 1

Part No. XG0105B

ME34-DV-2 Homefire

Maintenance

CAUTIONS

Fireplace gas control must be in the “OFF” position and pilot

and main burners extinguished when cleaning appliance with
a vacuum.

Doors and logs can get very hot. Handle only when cool.

General

Have the fireplace installation inspected yearly, including a visual

check of the vent system, the burner and the pilot flame. For your
convenience a 1/8" manifold pressure tap is supplied on the gas
valve for a test gauge connection. See Figure 28.

For Natural Gas this appliance requires a minimum inlet pressure

of 5.5" W.C. and a manifold pressure of 3.5" W.C.

For Propane Gas this appliance requires a minimum inlet pres-

sure of 11" W.C. and a manifold pressure of 10" W.C.

Always keep the fireplace area clear and free of combustible

materials, as well as gasoline and other flammable vapours and
liquids.

Do not use this appliance if

any part has been under water. Imme-

diately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control
which has been under water.

Operation

Lighting Instructions

See pages 14 and 15.

Cleaning

When the fireplace is first activated, there may be some smoking and
a visible film may be left on the glass. This is a normal condition, and
is the result of burning of protective coatings on new metal.

Glass must be cleaned periodically to remove any film (which is a

normal biproduct of combustion) which may be visible. Film can
easily be removed by removing the door, as shown on page 13.
Handle the door carefully, and clean it with non-abrasive glass
cleaners. One of the most effective products is Kel Kem.

Silicone seals on inner door during initial firing will "off gas", leav-

ing a visual deposit of a white substance on combustion cham-
ber walls. This can easily be removed using normal household
products.

Use a vacuum cleaner or whisk broom to keep the control com-

partment, burner, and firebox free from dust and lint.

Logs may be cleaned periodically with a vacuum to remove soot

or other contaminates. The logs are fragile and will break easily.

WARNING:

Do not attempt to clean glass when hot.
Do not clean glass with abrasive materials as any glass etch-
ing may cause premature glass failure.

Adjusting the Burner

Raising or lowering the Flame Height

he ME34-DV-2 fireplace is equipped with an adjustable burner, al-
lowing you to raise or lower the flames. Operating the control knob
as described below will adjust both the main burner and the ember
burner.

To raise the flame height, turn the black knob (located behind the

lower trim) counterclockwise.

To lower the flame height, turn clockwise.

Gas Control Knob

(Shown in "Pilot" postion.)

Figure 27.

Hi-Lo' Adjustment on the ME34-DV-2's gas valve.