Sensor Head Installation

(Side Mount Configuration)

OPS

Series Encoders

2.

Verify Sensor Mounting Surface Height

Refer to the OPS interface drawing for detailed dimensions.
Use Z-Height spacer shim to verify that the Z-Height distance between

the bottom surface of the sensor and the top of the scale is as follows:
Tape Scales:

Use red spacer (1.00mm) to set the proper Z-Height for

PurePrecision Marker Tape II and Laser Tape II Scales

Glass Scales:

Use blue spacer (0.83mm) to set the proper Z-Height for

PurePrecision Performance and Value Linear Glass Scales

See step 3 below for installation steps.

3.

Installation Steps

3.2 Place shim between the bottom of the sensor head

and the top of the scale and press down in the Z-axis.

Shim can be inserted either parallel or perpendicular

to the scale. The shim features cut-outs to allow

signal level to be monitored during sensor mounting.

Z

Y

X

q

z

Axis Diagram

3.1 Loosen the sensor in the Z-axis

3.4 Carefully remove the shim by rotating it off the

scale with the shim’s handle.

3.3 Tighten the sensor in the Z-axis.

Rotational

movement to

remove shim.

Gently push the

sensor and

mounting against

the top of the

tape scale in the

z-axis.

1.

Install the Sensor

Use a wrench and M3 screws to install the sensor. Refer to interface drawing to make sure sensor is oriented

properly with reference to the scale.