Sensor Head Installation

(Top Mount Configuration)

OPS

Series Encoders

Sensor Mounting Orientation and

Tolerances

Axis diagram.

OPS Top Mount Configuration

Sensor Alignment Tolerances

Axis

Alignment Tolerance

X

Direction of Motion

Y

± 0.20mm

Z

± 0.15mm

q

X

± 1.0°

q

Y

± 1.0°

q

Z

± 2.0°

Z

Y

X

q

z