Recommendations for Power; Installation

Considerations

OPS

Sensor Installation

1.

Recommendations for Power

OPS

encoders require a minimum of 4.75VDC continuously. When designing circuits and extension

cables, be sure to account for voltage loss over distance and tolerances from the nominal supply

voltage so that at least 4.75VDC is available to the OPS encoder under all operating conditions. The

input voltage should not exceed 5.25VDC.

2.

Installation Considerations

The OPS encoder is a precision electronic instrument. It has been designed to function in a wide

range of applications and environments. To take full advantage of the modular system design,

considerations should be made to allow easy access to the sensor for service and/or replacement.
For optimal performance and reliability:
DO follow standard ESD precautions while handling the sensor.
DO allow proper alignment clearance for sensor head alignment.
DO follow setup instructions for the encoder system.
DO, where possible, install the scales in an

“upside down” or vertical position to minimize accumulation of dust.
DO consider redundant encoders or additional feedback devices as part of an overall risk

management program for medical applications.
DO NOT store sensors in an uncontrolled environment.
DO NOT electrically overstress the sensor (Power supply ripple/noise).
DO NOT intentionally “hot swap” the sensor if the device is energized.
DO NOT use in high contamination applications (dust, oil, excessive humidity, or other airborne

contaminants).