Printer Commands
Chapter 5
400 Operators Manual
44
^A
^D
COMMAND
24
Change SW4: Change software dip switch #4. Below is the ^AB sequence.
12345678
^ABxxxxxxxx
*******.)
Always 0
******.))
Always 0
*****.)))
Always 0
****.))))
Always 0
***.)))))
1=Auto-size on Power-up, 0=Disable
**.))))))
1=Blow-hole Sensing Enable, 0=Disable
*.)))))))
Always 0
.))))))))
Always 0
Position:
1
Always 0
2
Always 0
3
Blow-hole Stock: Enable this position when using blow-hole or cut-slot stock:
Stock that uses a hole instead of a gap to separate labels.
4
Auto-size on power-up: When enabled, the printer automatically sizes the label
stock when turned on. The printer then uses these header values for all
subsequent label formats. See the ^D39 command in section 5.3 for more
information on auto-sizing.
5
Always 0
6
Always 0
7
Always 0
8
Always 0
^A
^D
COMMAND
XX
36
Adjust Contrast Base: Used to adjust the contrast base point for such things as
high-speed paper and printhead wear. This command is stored in the EEprom and
skews the entire contrast window (^D35). This command has a ^A range of 10 to
200%.