Microcom 400 User Manual
Page 47

Chapter 5
Printer Commands
400 Operators Manual
39
Enquiry Responses
TEXT
^ALPHA or CONTROL
CODE
DEFINITION
>RESTARTED<
>READY<
>DATA ERROR<
>LOW STOCK<
>LOW TEMP<
>OVER TEMP<
>OVER VDD<
>TAKE LABEL<
^Z
^F
^U
^Y
^^
^[
^\
^V
Printer has been reset
Normal condition
Communication error
Out of labels
Head temperature is low
Head temperature is high
VDD voltage is high
Printer is waiting for a label to be taken
Table 8
5.3
SENDING ^D PRINTER COMMANDS
Unless other-wise specified, these commands are entered by sending a ^DXX where XX is the
command number. It is followed by a carriage return or another control code. Some commands
load data or control numbers and are preceded by a ^AXX, where XX represents the data or
control number. Unless otherwise specified, command codes should precede or follow the actual
format layout. They should be placed before the ^D57 or just before the print command ^D3.
All commands not listed in 5.3.1 (the EEPROM and dip switch section) are not retained when the
printer is turned off and if desired, must be sent again upon power-up.
When possible, the following commands are grouped by function. See the quick reference
command summary in Appendix G for a listing by number.
Some commands can be substituted with equivalent control-codes. If this is the case, there will
be an equivalence statement in the description.
Example of Command usage:
^A3^D75^D35 (This sequence will print a batch of three labels).