beautypg.com

Startscan signal, Ssh signal, Figure 10 – Measurement Computing PCI-DAS6023 User Manual

Page 23: D figure 11

background image

PCI-DAS6023 and PCI-DAS6025 User's Guide

Functional Details

23

t

w

= 37.5 ns

minimum

Figure 10. A/D STOP TRIGGER input signal timing

Figure 11. A/D STOP TRIGGER output signal timing

STARTSCAN signal

The STARTSCAN output signal indicates when a scan of channels has been initiated. It may be programmed to

be available at any of the AUXOUT pins. The STARTSCAN output signal is a 50 ns wide pulse the leading

edge of which indicates the start of a channel scan.

Figure 12. STARTSCAN start of scan timing

SSH signal

The SSH signal can be used as a control signal for external sample/hold circuits. The SSH signal is

programmable polarity pulse that is asserted throughout a channel scan. The state of this signal changes after the

start of the last conversion in the scan. The SSH signal may be routed via software selection to any of the

AUXOUT pins. Figure 13 shows the timing for the SSH signal.

Figure 13. SSH signal timing

This manual is related to the following products: