beautypg.com

Aada, Aada -42 – Measurement Computing CB-7080 User Manual

Page 60

background image

CB-7080 & CB-7080D Counter/Timer User's Guide

@AADA

2-42

@AADA

Description

: Disable alarm (for alarm-mode 1). Refer to "

Counter alarm mode selection

" for more

information.

Syntax

: @AADA[chk](cr)

@

A delimiter character

AA

2-character HEX module address, from 00 to FF

DA

[chk]

2-character checksum. If checksum is disabled, no [chk]

(cr)

0x0D

Response

:

Valid response

!AA[chk](cr)

Invalid response

?AA[chk](cr)

no response

Syntax error, communication error or address error

!

A delimiter character indicating a valid response

?

A delimiter character indicating an invalid response

AA

2-character HEX module address

[chk]

2-character checksum. If checksum is disabled, no [chk]

(cr)

0x0D

Examples

:

Disable the alarm for module 1:

command:

@01DA(cr)

response:

!01(cr)

Disable the alarm for module 2:

command:

@02DA(cr)

response:

!02(cr)