CB-7080 & CB-7080D Counter/Timer User's Guide

$AA1H

2-13

$AA1H

Description

: Reads the high trigger level of non-isolated input. Refer to "

Programmable threshold voltage

setting

" on page 1-8 for more information.

Syntax

: $AA1H[chk](cr)

$

A delimiter character

AA

2-character HEX module address, from 00 to FF

[chk

2-character checksum. If checksum is disabled, no [chk].

(cr)

0x0D

Response

:

Valid response

!AA(data)[chk](cr)

Invalid response

?AA[chk](cr)

no response

Syntax error, communication error or address error

!

A delimiter character indicating a valid response

?

A delimiter character indicating an invalid response

AA

2-character HEX module address

(data)

2-character decimal value for high trigger level. The unit is 0.1 volt and the range

can be from 0.0 to 5.0 volts.

[chk]

2-character checksum. If checksum is disabled, no [chk].

(cr)

0x0D

Examples

:

High trigger level=2.4 volts:

command:$011H(cr)

response:

!0124(cr)

High trigger level=3.0 volts:

command:

$021H(cr)

response:!0230(cr)