CB-7080 & CB-7080D Counter/Timer User's Guide
$AA5NS
2-23
$AA5NS
Description
: Set the counter status
Syntax
: $AA5NS[chk](cr)
$
A delimiter character
AA
2-character HEX module address, from 00 to FF
N=0
counter 0
N=1
counter 1
S=0
stop counter
S=1
start counter
[chk
2-character checksum. If checksum is disabled, no [chk]
(cr)
0x0D
Response
:
Valid response
!AA[chk](cr)
Invalid response
?AA[chk](cr)
no response
Syntax error, communication error or address error
!
A delimiter character indicating a valid response
?
A delimiter character indicating an invalid response
AA
2-character HEX module address
[chk]
2-character checksum. If checksum is disabled, no [chk]
(cr)
0x0D
Examples
:
Stop counter 0:
command:
$01500(cr)
response:
!01(cr)
Start counter 1:
command:
$01511(cr)
response:
!01(cr)