Aa1h(data), Aa1h(data) -14 – Measurement Computing CB-7080 User Manual
Page 32

CB-7080 & CB-7080D Counter/Timer User's Guide
$AA1H(data)
2-14
$AA1H(data)
Description
: Sets the high trigger level of non-isolated inputs. Refer to "
Programmable threshold voltage
" for more information.
Syntax
: $AA1H(data)[chk](cr)
$
A delimiter character
AA
2-character HEX module address, from 00 to FF
(data)
2-character decimal value for high trigger level. The unit is 0.1 volt, and the range
can be from 0.0 to 5.0V.
[chk]
2-character checksum. If checksum is disabled, no [chk].
(cr)
0x0D
Response
:
Valid response
!AA[chk](cr)
Invalid response
?AA[chk](cr)
no response
Syntax error, communication error or address error
!
A delimiter character indicating a valid response
?
A delimiter character indicating an invalid response
AA
2-character HEX module address
[chk]
2-character checksum,
if checksum is disabled no [chk]
(cr)
0x0D
Examples
:
High trigger level=2.4 volts
command:
$011H24(cr)
response:
!01(cr)
High trigger level=3.0 volts
command:
$021H30(cr)
response:
!02(cr)
Note:
The default value for the high trigger level is 2.4V