Measurement Computing 6K-SSR-RACK08 User Manual
Page 15
6K-SSR-RACK08 User's Guide
Installing the 6K-SSR-RACK08
Table 2-4. Connector P9 pin out
Signal Name Pin
Pin Signal
Name
GND
50
• •
49
P10 Pass Through 99
P10 Pass Through 98
48
• •
47
P10 Pass Through 97
P10 Pass Through 96
46
• •
45
P10 Pass Through 95
P10 Pass Through 94
44
• •
43
P10 Pass Through 93
DIO7
42
• •
41
DIO6
DIO5
40
• •
39
DIO4
DIO3
38
• •
37
DIO2
DIO1
36
• •
35
DIO0
P10 Pass Through 84
34
• •
33
P10 Pass Through 83
P10 Pass Through 82
32
• •
31
P10 Pass Through 81
P10 Pass Through 80
30
• •
29
P10 Pass Through 79
P10 Pass Through 78
28
• •
27
P10 Pass Through 77
P10 Pass Through 76
26
• •
25
P10 Pass Through 75
P10 Pass Through 74
24
• •
23
P10 Pass Through 73
P10 Pass Through 72
22
• •
21
P10 Pass Through 71
P10 Pass Through 70
20
• •
19
P10 Pass Through 69
P10 Pass Through 68
18
• •
17
P10 Pass Through 67
P10 Pass Through 66
16
• •
15
P10 Pass Through 65
P10 Pass Through 64
14
• •
13
P10 Pass Through 63
P10 Pass Through 62
12
• •
11
P10 Pass Through 61
P10 Pass Through 60
10
• •
9
P10 Pass Through 59
P10 Pass Through 58
8
• •
7
P10 Pass Through 57
P10 Pass Through 56
6
• •
5
P10 Pass Through 55
P10 Pass Through 54
4
• •
3
P10 Pass Through 53
P10 Pass Through 52
2
• •
1
P10 Pass Through 51
Table 2-5. Connector P10 pin out
Signal Name Pin
Pin Signal
Name
GND
50
• •
49
P9 Pass Through 99
P9 Pass Through 98
48
• •
47
P9 Pass Through 97
P9 Pass Through 96
46
• •
45
P9 Pass Through 95
P9 Pass Through 94
44
• •
43
P9 Pass Through 93
DIO7
42
• •
41
DIO6
DIO5
40
• •
39
DIO4
DIO3
38
• •
37
DIO2
DIO1
36
• •
35
DIO0
P9 Pass Through 84
34
• •
33
P9 Pass Through 83
P9 Pass Through 82
32
• •
31
P9 Pass Through 81
P9 Pass Through 80
30
• •
29
P9 Pass Through 79
P9 Pass Through 78
28
• •
27
P9 Pass Through 77
P9 Pass Through 76
26
• •
25
P9 Pass Through 75
P9 Pass Through 74
24
• •
23
P9 Pass Through 73
P9 Pass Through 72
22
• •
21
P9 Pass Through 71
P9 Pass Through 70
20
• •
19
P9 Pass Through 69
P9 Pass Through 68
18
• •
17
P9 Pass Through 67
P9 Pass Through 66
16
• •
15
P9 Pass Through 65
P9 Pass Through 64
14
• •
13
P9 Pass Through 63
P9 Pass Through 62
12
• •
11
P9 Pass Through 61
P9 Pass Through 60
10
• •
9
P9 Pass Through 59
P9 Pass Through 58
8
• •
7
P9 Pass Through 57
P9 Pass Through 56
6
• •
5
P9 Pass Through 55
P9 Pass Through 54
4
• •
3
P9 Pass Through 53
P9 Pass Through 52
2
• •
1
P9 Pass Through 51
Information on signal connections
General information regarding signal connection and configuration is available in the Guide to Signal
Connections on our web site at
2-6