beautypg.com

Area of application, Composition – Ivoclar Vivadent Zenostar User Manual

Page 7

background image

7

Area of application

Indications

Zenostar are milling discs designed for the manufacture of single-tooth and multiple-unit restorations

*

used for tooth replacements.

Depending on the indication, Zenostar is suitable for the construction of frameworks and monolithic (full-contour) restorations.

Translucency

level

Indications

Crown
frameworks

Interlocked
crown
frameworks

Multi-unit
bridge
frameworks

*

Primary
telescope
crowns

Full-contour
crowns

Full contour,
interlocked
crowns

Full- contour,
multi-unit
bridges

*

Zenostar T

Zenostar MO

*In Canada, bridge indications are limited to no more than 6 units with no more than 2 adjacent pontics.

Contraindications

More than two connected pontics

Very deep subgingival preparation

Patients with severely reduced residual dentition

Veneered Zenostar T/MO restorations are not suitable for patients suffering from bruxism.

Two or more unsupported cantilever units

Any other use not listed in the indications

Temporary insertion

Additional limitations of use

Failure to observe the following restrictions may compromise the results achieved with Zenostar:

failure to observe the necessary minimum connector and minimum framework thicknesses

milling of the discs in non-compatible CAD/CAM units (only suitable for dry machining)

sintering in a non-compatible high-temperature furnace

Composition

Zirconium oxide (ZrO

2

+ HfO

2

+Y

2

O

3

) ≥ 99 %

10.5 ± 0.5

Yttrium oxide (Y

2

O

3

) > 4.5 – ≤ 6.0%

≥ 900

Hafnium oxide (HfO

2

) ≤ 5%

≥ 5.0

Aluminium oxide + other oxides ≤ 1.0 %

<10

Type / Class

Type II / Class 6