Ivoclar Vivadent Zenostar User Manual
Page 56

56
IPS e.max Ceram on Zenostar T – Staining Technique
IPS e.max Ceram
B
°C
S
min
t
°C/min
T
°C
H
min
V1
°C
V2
°C
Stain and
Characterization firing
403
6:00
60
770
1:00
450
769
Glaze firing
403
6:00
60
770
1:00-
2:00
450
769
Add-on after Glaze firing
403
6:00
50
770
1:00
450
699
If several objects (multi-unit bridges with massive bridge pontics or several full-contour restorations) are fired in one firing cycle, the
heating of the objects in the furnace may be delayed. This delay can be counteracted by either reducing the heating rate or by
extending the holding time at the final temperature.
The heating of the firing chamber depends on the type of furnace as well as the size of the firing chamber!
Firing parameters for IPS e.max Ceram
IPS e.max Ceram on Zenostar T/MO – Layering Technique
IPS e.max Ceram
B
°C
S
min
t
°C/min
T
°C
H
min
V1
°C
V2
°C
L
°C
ZirLiner firing
403
4:00
40
960
1:00
450
959
0
1
st
Margin firing
403
4:00
40
800
1:00
450
799
0
2
nd
Margin firing
403
4:00
40
800
1:00
450
799
0
Wash firing
403
4:00
40
750
1:00
450
749
0
1
st
Dentin-/Incisal firing
403
4:00
40
750
1:00
450
749
0
2
nd
Dentin-/Incisal firing
403
4:00
40
750
1:00
450
749
0
Stain firing
403
4:00
60
725
1:00
450
724
450
Glaze firing
403
4:00
60
725
1:00
450
724
450
Add-on with Glaze firing
403
4:00
60
725
1:00
450
724
450
Add-on after Glaze firing
403
4:00
50
700
1:00
450
699
450