beautypg.com

Ivoclar Vivadent Zenostar User Manual

Page 31

background image

31

Staining of the "outer" occlusal area using body shades

Customization of the "outer" fissures

Individual staining of the "outer" incisal area

Individual staining of the "inner" incisal area

Restoration after completion of the infiltration procedure

The stained restorations must be fully dried before they are sintered; otherwise the restorations and/or the sintering furnace may
be damaged. The restorations can be dried either using an infrared lamp or a drying cabinet. The drying time depends on the
temperature and the size of the restoration. With lower temperatures, drying takes longer. Large restorations also take longer to
dry. Drying temperatures higher than 140°C/284°F may lead to defects, as the resulting steam cannot escape quickly enough.
Refer to the table on the page 17 for recommended drying times. The specifications for the sintering procedure can be found on
page 18.