Ivoclar Vivadent Zenostar User Manual
Page 23

23
Zenotec sintering programs
For the sintering process in the Zenotec high-temperature furnaces, the following points should be observed:
If a standard program is used, it is recommended to sinter the restorations on a sintering support base plate under a high-purity
Al
2
O
3
cover. This arrangement helps prevent deformation and discolouration from occurring in the restoration. All standard
sintering programs are matched to this configuration.
If a fast sintering program is used, only the sintering support base plate - without the cover - must be used. Fast sintering is only
suitable for single-tooth restorations.
Check sintering auxiliaries regularly to make sure that they are clean and work properly.
J Zenotec Fire P1
Standard program 1450°C/2h (2642°F/2h):
Temperature 1
[°C] / [°F]
Temperature 2
[°C] / [°F]
Heating rate:
[°C/h] / [°F/h]
Holding time [h]
Heating phase
20/68
900/1652
600/1112
-
Holding phase
900/1652
900/1652
-
0.5
Heating phase
900/1652
1450/2642
200/392
-
Holding phase
1450/2642
1450/2642
-
2
Cooling phase
1450/2642
900/1652
600/1112
-
Cooling phase
900/1652
300/572
500/932
-
- switch off -
Zenotec Fire P1 fast sintering program:
Only suitable for single-tooth restorations!
Temperature 1
[°C] / [°F]
Temperature 2
[°C] / [°F]
Heating rate:
[°C/h] / [°F/h]
Holding time [h]
Heating phase
20/68
1520/2768
1500/2732
-
Holding phase
1520/2768
1520/2768
-
0.5
Cooling phase
1520/2768
300/572
800/1472
-
- switch off -