Ivoclar Vivadent Zenostar User Manual
Page 24

24
J Zenotec Fire Cube
Standard program 1500°C/2h (2732°F/2h):
Temperature 1
[°C] / [°F]
Temperature 2
[°C] / [°F]
Heating rate:
[°C/h] / [°F/h]
Holding time [h]
Heating phase
20/68
900/1652
600/1112
-
Holding phase
900/1652
900/1652
-
0.5
Heating phase
900/1652
1500/2732
200/392
-
Holding phase
1500/2732
1500/2732
-
2
Cooling phase
1500/2732
900/1652
600/1112
-
Cooling phase
900/1652
300/572
500/932
-
- switch off -
Quick sintering program:
Only admissible for single-tooth restorations!
Temperature 1
[°C] / [°F]
Temperature 2
[°C] / [°F]
Heating rate:
[°C/h] / [°F/h]
Holding time [h]]
Heating phase
20/68
1500/2732
1500/2732
-
Holding phase
1500/2732
1500/2732
-
0.5
Cooling phase
1500/2732
300/572
800/1472
-
- switch off -
See also other documents in the category Ivoclar Vivadent Equipment:
- 14K (2 pages)
- 24K (2 pages)
- BioUniversal KFG (2 pages)
- Callisto 86 (2 pages)
- Capricorn 15 (2 pages)
- Callisto 86 (2 pages)
- Harmony KF (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal E (2 pages)
- BioUniversal PdF (2 pages)
- Brite Gold (2 pages)
- Capricorn 15 (2 pages)
- Callisto Implant 33 (2 pages)
- Capricorn (2 pages)
- Colado CC (2 pages)
- Callisto 84 (2 pages)
- Callisto CP+ (2 pages)
- Callisto CPG (2 pages)
- Callisto Implant 60 (2 pages)
- CosmoPost (24 pages)
- Colado NC (2 pages)
- Elektra (2 pages)
- Evolution Lite (2 pages)
- ESPRIT (1 page)
- Elektra 10 (2 pages)
- IPS d.SIGN Ultra (2 pages)
- EP 5000 (1 page)
- Harmony 2 (2 pages)
- EP 600 (36 pages)
- Harmony Hard (2 pages)
- Harmony Medium (2 pages)
- Harmony Soft (2 pages)
- Heliobond (36 pages)
- Harmony 3 (2 pages)
- Harmony C&B 55 (2 pages)
- EP 600 Combi (40 pages)
- Harmony PF (2 pages)
- Harmony X-Hard (2 pages)
- IPS AcrylCAD (2 pages)
- IPS d.SIGN 30 (2 pages)
- IPS Classic (24 pages)
- IPS d.SIGN 59 (2 pages)
- IPS d.SIGN 84 (2 pages)
- IPS d.SIGN 96 (2 pages)