Telio cad, Cad/cam processing – Ivoclar Vivadent Telio Lab User Manual
Page 29

The fabrication steps are described in the directions for use and user manuals of the different CAD/CAM
systems. The instructions of the manufacturers must be followed.
Observe the stipulated minimum thicknesses and connector dimensions.
Important for the processing in Sirona milling devices
In comparison with ceramic materials, a reduced quantity of Dentatec fluid per tank filling is
required. Please refer also to the Ivoclar Vivadent abrasives overview.
The CAD-Waxx Starter Kit from Sirona with a modified tank and reinforced filter system
(from specialized dental dealers) is required for the processing in MC-L devices.
Telio CAD
CAD/CAM processing
Telio
CAD
–
CAD/CAM
pr
ocessing
29
Prevention of premature loss of retention:
Apart from a retentive preparation design, the reliable cementation of Telio CAD restorations using a
temporary luting material (e.g. Telio CS Link) depends on the accuracy of fit, which is determined by
the CAD/CAM system used.