Preparing and isolating the model, Completion, Polymerization in a water bath – Ivoclar Vivadent Telio Lab User Manual
Page 23

Preparing and isolating the model
– Remove the silicone key from the model once it is set and clean off any wax residue.
– Block out undercuts and cuts between model segments with wax.
– Immerse the model in water for 5 minutes. Then, apply two layers of Separating Fluid. Wait between
the two layers until the surface is no longer shiny.
Preparing and conditioning of the ground denture teeth
– Roughen the surface using rough rotary diamonds or blast with type 100 aluminium oxide
(2 bar/29 psi) if necessary.
– Place the roughened teeth in the silicone key and secure with a small amount of superglue.
– To condition the denture teeth, wet the roughened surfaces with Telio Lab Cold Liquid and allow a
reaction time of min. 2 to max. 4 minutes.
Completion
– Apply Telio Lab Dentin on the isolated model without air bubbles.
– Pouring Telio Lab and placing the silicone key on the isolated model.
– Once Telio Lab has reached its plastic phase, the material is polymerized under pressure in a water
bath for 15 minutes at 2-6 bar / 29-87 psi and a temperature of 40-50 °C / 104-122 °F.
Wetting with Telio Cold Liquid
Pouring Telio Dentin and placing the silicone key
Polymerization in a water bath
(e.g. Ivomat
®
IP3)
Pressure (bar/psi)
Temperature (°C/°F)
Time (min)
2–6/29–87
40–50/104–122
15
Telio
Lab
–
Fabricating
a
temporary
veneer
23