IPS e.max Ceram
B
S
t
➚
T
H
V
1
V
2
Veneer
°C/°F
min
°C/°F/min
°C/°F
min
°C/°F
°C/°F
Wash firing with IPS e.max Ceram Add-On
403/
8:00
50/
720/
1:00
450/
719/
757
8:00
90
1328
1:00
842
1326
Wash firing with IPS e.max Ceram Dentin/Transpa
403/
8:00
50/
780/
1:00
450/
779/
757
8:00
90
1436
1:00
842
1434
Cervical firing
403/
8:00
50/
770/
1:00
450/
769/
757
8:00
90
1418
1:00
842
1416
1
st
Dentin/Incisal firing
403/
8:00
50/
770/
1:00
450/
769/
757
8:00
90
1418
1:00
842
1416
2
nd
Dentin/Incisal firing
403/
8:00
50/
770/
1:00
450/
769/
757
8:00
90
1418
1:00
842
1416
Stain and Glaze firing
403/
8:00
50/
740/
1:00
450/
739/
757
8:00
90
1364
1:00
842
1362
– The parameters listed represent standard values and apply to the Ivoclar Vivadent furnaces: P300, P500, P700, EP 600,
EP 3000, EP 5000. The temperatures indicated also apply to furnaces of older generations, such as the P20, P80, P90,
P95, P100, P200 and PX1. If one of these furnaces is used, however, the temperatures may deviate by ± 10 °C/18 °F,
depending on the age and type of the heating muffle.
– If furnaces other than those from Ivoclar Vivadent are used, temperature adjustments may be necessary.
– Regional differences in the power supply or the operation of several electronic devices by means of the same circuit
may render adjustments of the firing and press temperatures necessary.
Firing of IPS e.max Ceram Veneers
– The firing parameters for the fabrication of veneers must be observed.
– The prolonged closing time ensures a gentle and complete drying of the refractory die material and thus enables to
achieve a homogeneous firing result.
– If furnaces other than those from Ivoclar Vivadent are used, temperature adjustments may be necessary.
– At the beginning, open the furnace and wait for the acoustic signal. Subsequently, place the firing tray with the objects
in the center of the firing table and start the program.
– Remove IPS e.max objects from the furnace after completion of the firing cycle (wait for the acoustic signal of the
furnace).
– Allow the objects to cool to room temperature in a place protected from draft.
– Do not touch the hot objects with metal tongs.
– Do not blast or quench the objects.
IPS e.max Ceram Veneers