Add-On firing
There are 3 IPS e.max Ceram Add-On materials available for adjustments. Depending on the individual application, the
materials are processed differently.
Option 1 – Add-On with Glaze firing
This method is used if minor adjustments are made together with the Glaze firing. If you use this method, proceed
as follows:
– If IPS e.max Ceram Glaze Spray is used for glazing, spray it once the Add-On
materials have been applied.
– If necessary, optimize the accuracy of fit of the shoulder using IPS e.max Ceram
Add-On Margin (alone).
– Mix IPS e.max Ceram Add-On Dentin and Incisal in a 1:1 ratio and then mix it with
Dentin and Transparent Incisal material. Apply the mixture on the corresponding
areas and fire.
– Polish the adjusted areas to a high gloss after firing.
Firing parameters for Add-On with Glaze firing – note the slow cooling!
Firing parameters for Add-On after Glaze firing – note the slow cooling!
Option 2 – Add-On after Glaze firing
Additional corrections may be required once the restoration has been completed and tried in with the patient (e.g. pontic
rest, contact points). In such cases, proceed as follows:
– Apply IPS e.max Ceram Add-On Dentin and Incisal (alone) to the corresponding
areas and fire.
– Polish the adjusted areas to a high gloss after firing.
Pr
ocessing
on
ZrO
2
Frameworks
IPS e.max Ceram on ZrO
2
B
S
t
➚
T
H
V
1
V
2
L
°C/°F
min
°C/°F/min
°C/°F
min
°C/°F
°C/°F
°C/°F
Add-On with Glaze firing
403/757
6:00
60/108
725/1337
1:00
450/842
724/1335
450/842
IPS e.max Ceram on ZrO
2
B
S
t
➚
T
H
V
1
V
2
L
°C/°F
min
°C/°F/min
°C/°F
min
°C/°F
°C/°F
°C/°F
Add-On after Glaze firing
403/757
6:00
50/90
700/1292
1:00
450/842
699/1290
450/842