Before the application of the ZirLiner, clean the abutment with the steam jet.
Do not blast with Al
2
O
3
or glass polishing beads.
Cover the entire abutment with the tooth-shaded or gingiva-shaded ZirLiner
Place the abutment on a honey-combed firing tray for ZirLiner firing. Before firing, make sure
that the contact surface between the abutment and the implant is free from contamination.
Firing parameter for the ZirLiner firing
IPS e.max Ceram ZirLiner on Straumann
®
B
S
t
➚
T
H
V
1
V
2
L
Anatomic IPS e.max
®
Abutment
°C/°F
min
°C/°F/min
°C/°F
min
°C/°F
°C/°F
°C/°F
ZirLiner firing
403/ 757
4:00
40/72
960/1760
1:00
450/842
959/1758
See also other documents in the category Ivoclar Vivadent Equipment:
- 14K (2 pages)
- 24K (2 pages)
- BioUniversal KFG (2 pages)
- Capricorn 15 (2 pages)
- Callisto 86 (2 pages)
- Harmony KF (2 pages)
- Callisto 86 (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal E (2 pages)
- BioUniversal PdF (2 pages)
- Brite Gold (2 pages)
- Capricorn 15 (2 pages)
- Callisto Implant 33 (2 pages)
- Capricorn (2 pages)
- Colado CC (2 pages)
- Callisto 84 (2 pages)
- Callisto CP+ (2 pages)
- Callisto CPG (2 pages)
- Callisto Implant 60 (2 pages)
- CosmoPost (24 pages)
- Colado NC (2 pages)
- Elektra (2 pages)
- Evolution Lite (2 pages)
- ESPRIT (1 page)
- Elektra 10 (2 pages)
- IPS d.SIGN Ultra (2 pages)
- EP 5000 (1 page)
- Harmony 2 (2 pages)
- EP 600 (36 pages)
- Harmony Hard (2 pages)
- Harmony Medium (2 pages)
- Harmony Soft (2 pages)
- Heliobond (36 pages)
- Harmony 3 (2 pages)
- Harmony C&B 55 (2 pages)
- EP 600 Combi (40 pages)
- Harmony PF (2 pages)
- Harmony X-Hard (2 pages)
- IPS AcrylCAD (2 pages)
- IPS d.SIGN 30 (2 pages)
- IPS Classic (24 pages)
- IPS d.SIGN 59 (2 pages)
- IPS d.SIGN 84 (2 pages)
- IPS d.SIGN 96 (2 pages)