Ivoclar Vivadent IPS e.max Ceram User Manual
Page 50

50
Apply the Gingiva materials according to the clinical situation.
Gingiva G1
Gingiva G2
Essence E22
Gingiva G3
Gingiva G5
Complete the tooth-shaded portions of the restoration using Incisal and Impulse materials for the second Dentin/Incisal firing.
Firing parameters for IPS e.max Ceram Gingiva
IPS e.max Ceram
B
S
t
➚
T
H
V
1
V
2
Cut-Back and layering technique
°C/°F
min
°C/°F/min
°C/°F
min
°C/°F
°C/°F
ZirLiner firing
403/
4:00
40/
960/
1:00
450/
959/
757
72
1760
842
1758
1
st
Dentin/Incisal firing
403/
4:00
40/
750
1:00
450/
749/
757
72
1382
842
1380
2
nd
Dentin/Incisal firing
403/
4:00
40/
750/
1:00
450/
749/
757
72
1382
842
1380
1
1
1
1
2
2
2
2
2
2
3
3
3
3
4
4
4
5
5
See also other documents in the category Ivoclar Vivadent Equipment:
- 14K (2 pages)
- 24K (2 pages)
- BioUniversal KFG (2 pages)
- Callisto 86 (2 pages)
- Capricorn 15 (2 pages)
- Callisto 86 (2 pages)
- Harmony KF (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal E (2 pages)
- BioUniversal PdF (2 pages)
- Brite Gold (2 pages)
- Capricorn 15 (2 pages)
- Callisto Implant 33 (2 pages)
- Capricorn (2 pages)
- Colado CC (2 pages)
- Callisto 84 (2 pages)
- Callisto CP+ (2 pages)
- Callisto CPG (2 pages)
- Callisto Implant 60 (2 pages)
- CosmoPost (24 pages)
- Colado NC (2 pages)
- Elektra (2 pages)
- Evolution Lite (2 pages)
- ESPRIT (1 page)
- Elektra 10 (2 pages)
- IPS d.SIGN Ultra (2 pages)
- EP 5000 (1 page)
- Harmony 2 (2 pages)
- EP 600 (36 pages)
- Harmony Hard (2 pages)
- Harmony Medium (2 pages)
- Harmony Soft (2 pages)
- Heliobond (36 pages)
- Harmony 3 (2 pages)
- Harmony C&B 55 (2 pages)
- EP 600 Combi (40 pages)
- Harmony PF (2 pages)
- Harmony X-Hard (2 pages)
- IPS AcrylCAD (2 pages)
- IPS d.SIGN 30 (2 pages)
- IPS Classic (24 pages)
- IPS d.SIGN 59 (2 pages)
- IPS d.SIGN 84 (2 pages)
- IPS d.SIGN 96 (2 pages)