CONTENTS

5

Safety Precautions and Installation Guidelines

To ensure reliable and safe long-term operation, please note the following installation
guidelines:

Do not use CATx-devices to link between buildings – please use fiber devices.

Only use in dry, indoor environments.

If the building has 3-phase AC power, try to ensure that equipment connected to
the Local and Remote units is on the same phase.

Try not to route a CATx link cable alongside power cables.

Ensure that the system connected to the Local unit is connected to power
ground.

Ensure that the monitor connected to the Remote unit is connected to power
ground and does not use an isolated power supply.

The Remote unit, Local unit and any power supplies can get warm. Do not
locate them in an enclosed space without any airflow.

Do not place a power supply directly on top of a unit.

Do not obstruct a unit’s ventilation holes.

To safeguard against personal injury and avoid possible

damage to equipment or property, please observe the
following:

Only use power supplies originally supplied with the

product or manufacturer-approved replacements. Do not
attempt to dismantle or repair any power supply. Do not

use a power supply if it appears to be defective or has a
damaged case.

Connect all power supplies to grounded outlets. In each

case, ensure that the ground connection is maintained
from the outlet socket through to the power supply’s AC
power input.

Do not attempt to modify or repair this product, or make

a connection from the CATx link interface (RJ45) or the

Fiber link interface (SC-Duplex) to any other products,
especially telecommunications or network equipment.

To comply with CE regulations, it is NOT allowed, to use
CATx devices with unshielded CATx cables