15

Commissioning

Manufacturer

Brand Name

Manufacturer

Brand Name

Amoco

Rykon 46

Gulf

46AW

Ashland Valvoline

Evergol 46

Mobil

DTE 20 Series 25

Atlantic Richfield

Duro AW-S-215

Mobil

DTE 10 Series 19

BP

Energol HLP

Pennzol

Magnus A 315

Chevron USA

AW Hydraulic Oil 46

Phillips Petroleum Corp.

Tellus 46

Citgo Petroleum Corp.

A/W Pacemaker XD-46

Shell

Tellus T46

Citgo Petroleum Corp.

A/W 46

Shell

SUNTAC WR 150 WR

Conoco (Continental)

Super Hydraulic Oil 21

Texaco

Rando HD 46

Esso

Nuto H46

Union

Hydraulic Oil Unax AW 215

Exxon

Nuto H46

Registered trademarks: Amoco

®

- Amoco Oil Company: Ashland Valvoline

®

- Ashland, Inc.; Atlantic Richfield

®

- Atlantic Richfield Co.; BP

®

- BP p.l.c; Chevron

®

USA - Chevron Intellectual Property

LLC; Citgo

®

Petroleum Corp. - Citgo Petroleum Corp.; Conoco

®

(Continental) - ConocoPhillips; Esso

®

and Exxon

®

- ExxonMobil; Gulf

®

- GULF Oil International; Mobil

®

- ExxonMobil; Pennzoil

®

-

SOPUS Products; Phillips Petroleum

®

Corp. - Phillips 66; Shell

®

- SOPUS Products; Texaco

®

- Chevron Intellectual Property LLC: Union

®

- Phillips 66.

Filling Reservoir
Pump hydraulic oil through an adequate filter into reservoir. Fill until
oil level indicator is

2

/

3

-

3

/

4

full. Inspect for leaks. Reservoir capacity is

70 liters (18.5 gal.). Approximately 55 liters (14.5 gal) will be needed for
the reservoir. If installation is completed with empty hoses, extra oil will
be needed to meet the

2

/

3

-

3

/

4

tank fill indicator requirement.

Hydraulic Oil
Harken recommends mineral-based, ISO 46 grade oil. Refer to Oil
Equivalent Table below. If HPU is primarily used in an extreme cold
weather environment, ISO 32 is suitable.
Characteristics of good quality, mineral-based hydraulic oil are:
• Good anti-wear performance
• Resistance to oxidation depredation
• Protection against rust and corrosion
• Resistance to foaming
• Ability to separate water rapidly
• Suitable for widely varying temperature conditions
• Good low temperature flow properties
• Retains viscosity/temperature characteristics while in service
• Universally available
Note: If the hydraulic installation was completed with empty hoses,

be sure to have extra oil on hand to top off the tank as the

hoses are filled.

Oil Level

Indicator

CAUTION! Never run the HPU pump without oil. This will void warranty.

When commissioning hydraulic equipment, it is extremely important to carefully follow each procedure to avoid premature system damage
and/or failure. Secure connections, ensure cleanliness, confirm proper fluid levels and perform all recommended tests. The following are
instructions to ensure proper commissioning of your Hydro 2.