background image

Guntermann & Drunck GmbH

Installation and operating manual
TripleMUX/QuadMUX

Pressing

ENTER

will run the function and the following info window will be

opened.

Info

TripleMUX

This function will delete

all settings.

Press Enter to continue

or

Esc to cancel


Confirm this once more by pressing the

ENTER

key. The window will change to

the FUNCTION menu.

5.2.3

Cascade setup


Note:
To run this function you need to be logged on as a master!

In the Cascade Setup menu you determine which terminal has been
connected to the four possible PC channels. The following are available:

PC (default assignment)

• MUX4 (permits the number of computers to be increased to up to 16

computers by using a miniMUX4. However, the access to the multi-way
graphic is only possible on the PCs directly connected to the TripleMUX.
All PCs connected via a miniMUX4 to the TripleMUX transmit only one
graphics signals on the other hand.).


A comprehensive description of cascading the TripleMUX using a miniMUX4 can
be found in the relevant manual.

Open the AdonIS for the TripleMUX using the HotKey combination you have
set or using the default HotKey

CRTL

+

NUM

.


In the open AdonIS ("Select Scene" menu) press the

F4

key

In the open "Cascade Setup" menu you set for each channel which device is
connected here. The

Space

key can be used to change the entries. By default

the value here is set to "PC". Pressing the

Space

key allows you to switch the

entry to "miniMUX 4".

To save your inputs, press the

F1

key. This will return you to the Select Scene

menu.