beautypg.com

2 the individual functions – Guntermann & Drunck TripleMUX User Manual

Page 17

background image

Guntermann & Drunck GmbH

Installation and operating manual
TripleMUX/QuadMUX

5.2

The individual functions

Key

F1

Back to the SELECT SCENE menu

5.2.1

AutoScan function

Key

F2

Triggering the AutoScan function

Activating the AutoScan function causes the automatic interconnection of all
channels.

Even unassigned channels or computers which are switched off can be
included in the AutoScan function (e.g. to check the boot phase).

5.2.1.1 Opening the AutoScan function

Open the AdonIS; key combination (default):

CRTL + NUM

. You can open the

AutoScan function, as described above, directly from the Select Scene menu,
as well as from the FUNCTION menu.

Then press

F 2

.


The enabled channels will now be switched to your console in sequence for
approx. 5 seconds. This time period can be changed

(see point 5.2.1.4)

5.2.1.2 Identifying the AutoScan function


The activated Scan function is indicated by the "Scan" display.

001

(Scene name, can be edited)

TripleMUX

(Console name, can be edited)

Scan

( Active Scan function )

5.2.1.3 Clearing the AutoScan function

In the event of inputs via the keyboard or mouse, the AutoScan function is
paused and is only enabled once again after the final character. The function is
closed by opening the AdonIS (

CRTL

+

NUM

) or a scene selection via HotKey.

The Scan display will go out.

5.2.1.4 Setting the AutoScan time

see point 5.2.2.1

Page 17