5.2.2.8 Setting the menu position / size
Change the position and size of all AdonIS windows here. Move the cursor to
the relevant entry in the Console Setup menu.
Pressing the
ENTER
key will take you to edit mode and you can then use the
arrow keys or the mouse to move the display to the required position.
M E N U P O S I T I O N T r i p l e M U X
Esc
Enter
F1:Save
To ensure optimum legibility of the AdonIS at all resolutions, the size of the
display can be changed using the Page up + Page down keys with a monitor
resolution greater than 640 x 480.
ENTER
completes the input and takes you back to the Console Setup (saved
temporarily).
To save the settings, close the Console Setup using
F1
(saved permanently).
5.2.2.9 Setting the Scancode Set
Note:
To run this function you need to be logged on as a master!
The scancode designates the "language" in which the keyboard communicates
with the computer. The TripleMUX works in scancode 2.
Only carry out this setting in consultation with our service department.
Move the cursor to the relevant entry.
By pressing the
SPACE
key you can select between the following alternatives:
3 or 2.
5.2.2.10 AdonIS by mouse
Here you can activate the support for the special buttons on the Intelli-Explorer
mouse for working with the TripleMUX. If you set the entry here to "Yes", the
AdonIS
,
can be opened by pressing button 4 or 5 on the Explorer mouse (left
side buttons) as well as using the keyboard.