Grandstream GXW42xx User Manual User Manual
Page 50

FIRMWARE 1.0.5.8
GXW42XX USER MANUAL
PAGE 48 OF 62
Jitter Buffer Type
Select either Fixed or Adaptive based on network conditions.
Jitter Buffer
Length
Select Low, Medium or High based on network conditions.
High (initial 200ms, min 40ms, max 600ms) Note: not all vocoders can meet the high
requirement
Medium (initial 100ms, min 20ms, max 200ms)
Low (initial 50ms, min 10ms, max 100ms)
SLIC Setting
Depends on standard phone type (and location)
Caller ID Scheme
Select the value according to the local Telco standard where the GXW42XX is installed.
Please refer to the pull down list to select.
Polarity Reversal
Default is No
. If set to “Yes”, polarity will be reversed upon call establishment and termination.
Loop Current
Disconnect
Set to Yes if the traditional PBX you are using with GXW42XX uses this method for signaling
call termination. Default is No.
Loop Current
Disconnect
duration
Default is 200.In 100 - 10000 milliseconds range.
Enable Hook
Flash
If no, flash will be treated as an on hook event.
Hook Flash
timing(Minimum)/
(Maximum)
Sets the minimum/maximum time the phone is on hook before being detected as a hook flash.
The range is 40 to 2000 milliseconds
On Hook Timing
Sets the time required to detect that the phone is on hook. The range is 40 to 2000
milliseconds. Default is 400 milliseconds.
Gain
Handset volume adjustment. RX is for receiving volume (direction FXSto analog phone), TX
is for transmission volume (Analog phone to FXS). Default values are 0dB for both
parameters. Loudest volume: +6dB Lowest volume: -6dB.
Disable Line Echo
Canceller (LEC)
Default is No
. If set to “Yes”, device will not use LEC to remove echo from a voice
communication.
SLIC Setting
Depends on standard phone type (and location)
Caller ID Scheme
Select the value according to the local Telco standard where the GXW42XX is installed.
Please refer to the pull down list to select.