CARD Suite Information for Addressable Amplified Speaker No. 4:
In this example, Addressable Amplified Speaker No. 4 is part of the East Campus and Dorm Zone areas
and can be accessed via addresses 104#, 112#, 113# and 99#. If any other code is entered, Speaker 4 will
remain inactive. Other notable programmed parameters for this speaker are:
Addresses 104, 112, and 113 will provide a contact closure output when active, but it will deactivate
within a few seconds after the broadcast has ceased.
Address 99 (All Call) will also provide a contact closure output when active, but the closure will
remain active for 3.00 seconds after the broadcast has ceased.
Low Battery Alert is not activated.
It is programmed for Voice Switch Mode with a voice switch silence limit programmed for 5
seconds.
Automatic Level Adjustment is disabled.