Jumpers
The default setting of the circuit board jumpers provide normal operation and should be changed only for
special applications. Remove the cover of the ITA2000A to access these jumpers. The “A” and “B”
positions are indicated on the PCBA.
Jumper Table
A = Active High B = Active Low
Jumper
No.
Default
Value
Description
JU2 B
Radio
PTT
JU3
B
Channel Steer Output 4
JU4
B
Channel Steer Output 3
JU5
B
Channel Steer Output 2
JU6
B
Channel Steer Output 1
JU7
B
Channel Steer Output 0
JU8
B
Accessory CSQ Output
JU9
B
Accessory PTT Output
JU10
B
Channel Steer Output 4
JU11
B
Channel Steer Output 3
JU12
B
Channel Steer Output 2
JU13
B
Channel Steer Output 1
JU14
B
Channel Steer Output 0
−20 dB
Out
Reduces radio RX by −20 dB
JU20
2W
Select 2-wire/4-wire audio
JU21
2W
Select 2-wire/4-wire audio
JU22
In
Enables audio hybrid for 2-wire configuration
JU24
2W
Select 2-wire/4-wire enable
JU30
Out
Converts the B+ supply to a 15 V power supply to increase audio
output.
JU31
Pins 1 and 2
Pins 2 and
3*
Selects Channel Steer 4 Output.
Selects J3-9 as alternate dc input.
*If pins 2 and 3 are selected, Channel Steer Bit 4 will be disabled.