GAI-Tronics ITA2000A ITA2000A Series Tone Remote Adapter with Scanning User and Installation Manual User Manual
Page 25
ITA2000A Series Tone Remote Adapter
Installation
21
03/13
ITA2000A to Kenwood TK-790/890 Series Radio Connection Chart
Adapter
Pin
Adapter
Function
Wire Color
Radio
Connector Pin
Radio Function
1
Channel steer 3 Blk w/white stripe
5
Auxiliary input 4 (programmable)
2
CSQ Detect IN Blue w/white stripe
8, 20 , 21, 22
Auxiliary output 2
(program to COR)
3
RX audio +
Green
17
RX audio signal output
4 AGND
Black
7
Earth
5
Channel steer 2 White w/blk stripe
4
Auxiliary input 3 (programmable)
6
PTT
White
6
Auxiliary input 5
(program to PTT)
7
Monitor
Orange
5
Auxiliary input 4
(program to MON)
8
Channel steer 0 Red
2
Auxiliary input 1 (programmable)
9
Channel steer 4 Red w/white stripe
5
Auxiliary input 4 (programmable)
10
CTCSS IN
Grn w/white stripe
N/C
11
RX audio –
Grn w/black stripe
7
Earth. Connected internally to
15D pin 4 at radio end of cable.
12
TX audio +
Blue
13
MIC/Data input signal 1
13
14
Monitor low
Orange w/blk stripe
7
Earth. Connected internally to
15D pin 4 at radio end of cable.
15
Channel steer 1 Red w/black stripe
3
Auxiliary input 2 (programmable)
Connector
Housing
Shield
Connected
internally to 15D
pin 4 at radio end
of cable.
N
OTES
:
The Carrier Detect Signal (COR) must be programmed to an auxiliary output pin. The Radio
Connection Chart shows COR programmed to auxiliary output 2, which is pin 8 of the radio
connector. Carrier Detect is Active High (SW1-2 = DN).
The PTT signal must be programmed to an auxiliary input 5, as per the Radio Connection Chart.
If the monitor function is required, the MON signal must be programmed to auxiliary input 4, as per
the Radio Connection Chart. Programming the MON signal alters the maximum number of channels
that can be scanned. Normally, a maximum of 15 channels can be scanned, however, use of the
MON function limits the maximum to 8 channels. Pin 7 of the adapter must be connected to the RX
CTCSS Disable Input (MON) pin of the radio. Pin 14 of the adapter must be connected to GRND.