GAI-Tronics ICS Hazardous Area Page/Party Stations User Manual
Page 5

Pub. 42004-723L2G
ICS Hazardous Area Page/Party
®
Station
Page 3 of 31
f:\standard ioms - current release\42004 instr. manuals\42004-723l2g.doc
11/14
These enclosures must be installed by trained, qualified and
competent personnel. Installation must comply with state and
national regulations, as well as safety practices for this type of
equipment.
WARNING
Do not install this equipment in
hazardous areas other than those indicated on the
approval listing in the “Specifications” section of this
manual. Such installation may cause a safety hazard and
consequent injury or property damage.
The mounting location must be flat and provide proper
clearance, rigidity and strength to support the enclosure and all
contained devices. The enclosures are equipped with factory-
installed hinges. The enclosures should be mounted with
hinges on the left.
WARNING
Do not mount the enclosure with
hinges on the top or bottom side.
Securely fasten the enclosure to the mounting location, using
3/8-inch (10mm) diameter steel mounting bolts and washers,
or washer head bolts.
WARNING
Do not disconnect equipment while energized.
Insure proper grounding to protective earthing.
Inspect and clean the machined flange flame joint surfaces of both the cover and box. Surfaces must be
smooth, free of nicks, scratches, dirt or any foreign particle build-up that would prevent a proper seal.
Surfaces must seat fully against each other to provide a proper explosion-proof joint. Clean surfaces by
wiping with a clean lint-free cloth.
Apply a light coat of Killark “LUBG” lubricant to flange surfaces and close the cover. Install and tighten
all cover bolts to 30 ft.-lbs. Make certain no cover bolts are omitted. Use only those bolts supplied with
the enclosure.
When installing an add-on station, consult the appropriate system layout diagrams. These figures, when
used in conjunction with the station installation information and cable layout guide, should provide all the
information necessary to install additional Page/Party stations.
Figure 2. ICS Hazardous Area Multi-
Party Station