Handset Amplifier
Output level (compression controlled) .................................................... 1.5 V
RMS
nominal into 33-ohm load
Adjustable 0–2.1 V
RMS
Frequency response ........................................................................... 250–6,500 Hz, +0/−3 dB ref. to 1 kHz
Distortion ......................................................................... <1.5% THD @ 1 kHz (below compression level)
Receiver level................................................................................................................. 200 mV
RMS
, nominal
Adjustable 150–400 mV
RMS
Speaker Amplifier
Maximum output:
8-ohm speaker* ....................................................... 30 watts into 8-ohm load with 1.5 V
RMS
input page level
Adjustable to 30 watts; default: 4 watts @ 8 ohms
16-ohm speaker ..................................................... 15 watts into 16-ohm load with 1.5 V
RMS
input page level
Adjustable to 15 watts; default: 2 watts @ 16 ohms
Frequency response ........................................................................... 250–6,500 Hz, +0/−3 dB ref. to 1 kHz
Distortion ...................................................................................................... <1% THD @1 kHz to 24 watts
<3% THD @ 1 kHz to 30 watts
Input impedance ......................................................................................................................... 50,000 ohms
16 kilohms with SmartSeries option
SmartSeries offset level adjustment range .................................................................................... 0 to 30 dB
*See Figure 19 on page 31.
Enclosure Specifications
Construction/finish ......................................................................... Cast aluminum/gray epoxy powder coat
Mounting ................................................... Wall or column, four 3/8-inch (10mm) mounting feet with slots
Connections................................................................................ Internal screw-type barrier terminal blocks
Dimensions ........................................... 14.31 H
13.06 W 11.68 D inches (363.6 331.8 296.6 mm)
Temperature range (operating and storage) ........................................... (−4º F to +140º F) −20º C to +60º C
Shipping weight ................................................................................................................... 49 lbs. (22.2 kg)
Net weight ............................................................................................................................ 47 lbs. (21.3 kg)
Enclosure ................................................................................................................................ IP66/Type 4X
VLC Option Specifications
VLC minimum input level .............................................................................................................. 50 mV
RMS
VLC tolerance ......................................................................................................................... 50 kHz +/−4%
All Call Option Specifications
All Call control output ..................................................................Sink 50 mA maximum to circuit common
pulled up to 24 V dc maximum
RTU Option Specifications
Output Relay
Maximum load current ................................................................................. 8 amps OUTPUT 1A (unfused)
1.6 amps OUTPUT 1B (fused)
Maximum voltage ............................................................................................................................. 250 V ac