The following tables are provided to aid qualified service personnel in troubleshooting problems with the
ICS Page/Party
®
Station.
Table 1. General Troubleshooting
Problem Potential
Cause
Station not
functional
Refer to the “Field Wiring” section on page 6 for proper terminations.
Verify incoming supply voltage at TB2 or TB3 on the Termination PCBA.
Verify regulated 24 V dc at P1 of Termination PCBA. Caution! Supply
voltage present at P2.
Excessive hum or
buzz during
station operation.
Inspect the Page/Party
®
lines for proper line terminations, shorts, and grounds.
Crosstalk occurs
between
Page/Party
®
lines.
Inspect the Page/Party
®
lines for proper line terminations, shorts, and
grounds.
Inspect the Page/Party
®
party line connections for crossing of the cable pairs.
Feedback occurs
during page.
Check location and orientation of speakers in the area.
Refer to the “Field Wiring” section related to mutual muting on page 6.
Refer to Speaker Mute on page 10.
Squeal in handset
receiver.
Ensure proper termination on Page/Party
®
lines.
Ensure system line balance is connected.
Handset
microphone audio
is too low/loud.
Disconnect headset, if connected.
Refer to the “Transmit Level” section on page 11.
Check jumper settings or cable connections at P4.
Ensure proper termination on Page/Party
®
lines.
Check handset connections.
Check proper cable terminations between Termination and Main PCBAs.
Check operation of hookswitch.
Replace handset.
Handset receiver
audio is too
low/loud.
Refer to “Receiver Volume” on page 11.
Check jumper settings or cable connections at P4.
Ensure proper termination on Page/Party
®
lines.
Check handset connections.
Check proper cable terminations between Termination and Main PCBAs.
Check operation of hookswitch.
Replace handset.