beautypg.com

GAI-Tronics ICS Hazardous Area Page/Party Stations User Manual

Page 28

background image

Pub. 42004-723L2G

ICS Hazardous Area Page/Party

®

Station

Page 26 of 31

f:\standard ioms - current release\42004 instr. manuals\42004-723l2g.doc
11/14

The following tables are provided to aid qualified service personnel in troubleshooting problems with the
ICS Page/Party

®

Station.

Table 1. General Troubleshooting

Problem Potential

Cause

Station not
functional

 Refer to the “Field Wiring” section on page 6 for proper terminations.
 Verify incoming supply voltage at TB2 or TB3 on the Termination PCBA.
 Verify regulated 24 V dc at P1 of Termination PCBA. Caution! Supply

voltage present at P2.

Excessive hum or
buzz during
station operation.

Inspect the Page/Party

®

lines for proper line terminations, shorts, and grounds.

Crosstalk occurs
between
Page/Party

®

lines.

 Inspect the Page/Party

®

lines for proper line terminations, shorts, and

grounds.

 Inspect the Page/Party

®

party line connections for crossing of the cable pairs.

Feedback occurs
during page.

 Check location and orientation of speakers in the area.
 Refer to the “Field Wiring” section related to mutual muting on page 6.
 Refer to Speaker Mute on page 10.

Squeal in handset
receiver.

 Ensure proper termination on Page/Party

®

lines.

 Ensure system line balance is connected.

Handset
microphone audio
is too low/loud.

 Disconnect headset, if connected.
 Refer to the “Transmit Level” section on page 11.
 Check jumper settings or cable connections at P4.
 Ensure proper termination on Page/Party

®

lines.

 Check handset connections.
 Check proper cable terminations between Termination and Main PCBAs.
 Check operation of hookswitch.
 Replace handset.

Handset receiver
audio is too
low/loud.

 Refer to “Receiver Volume” on page 11.
 Check jumper settings or cable connections at P4.
 Ensure proper termination on Page/Party

®

lines.

 Check handset connections.
 Check proper cable terminations between Termination and Main PCBAs.
 Check operation of hookswitch.
 Replace handset.