beautypg.com

GAI-Tronics ICS Hazardous Area Page/Party Stations User Manual

Page 33

background image

Pub. 42004-723L2G

ICS Hazardous Area Page/Party

®

Station

Page 31 of 31

f:\standard ioms - current release\42004 instr. manuals\42004-723l2g.doc
11/14

RTU Input Control (with SmartSeries Option)
Switch type................................................... Normally open (N.O.) or normally closed (N.C.) dry contacts
End-of-line termination ................................................................. 20 kilohms, or 15 kilohms + 5.1 kilohms
Cable resistance .................................................................................... 100 ohms maximum loop resistance
Contact closure resistance ............................................................................................... 1 kilohm maximum
Open fault detection ................................................................................................................... >65 kilohms
Short fault detection ..................................................................................................................... <200 ohms
Approvals
NRTL listed ............................................................. Hazardous locations Class I, Div. 1, Groups B, C & D;
(USA and Canada)

Class II, Div. 1, Groups F & G;

Class III, Div. 1

T6,

Type

4X

CE Mark

Certificate No.
Notified Body Id No. 0539
UL International DEMKO A/S
Lyskear 8
DK-2730 Herlev
Denmark

DEMKO 09 ATEX 0909372 (ATEX) .......................................................... II 2 G Ex d [ib] IIB + H

2

T6

IECEx UL 09.0009 (IECEx) .......................................................................... II 2 G Ex d [ib] IIB + H

2

T6

Typical Continuous Speaker Output Power Derating

1kHz Sinewave into a 8-ohm Load

0

5

10

15

20

25

30

0.1

1

10

100

Minutes

W

a

tts

-30°C

25°C

40°C

50°C

60°C

70°C

Figure 19. Typical Continuous Speaker Output Power Derating

1 kHz Sine Wave into an 8-ohm Load