Table 3. Troubleshooting SmartSeries Configurations

Problem Potential

Cause

Speaker volume is
too low/loud.

 Refer to the ADVANCE System Programming manual, Pub. 42004-700L2,

for station configuration.

 Refer to the “ALS Minimum Level”, “ALS Offset Level”, and “SmartSeries

VLC Level” sections.

 Check cable connection at P4.
 Ensure P15 and P16 are in the correct position for the application.
 Ensure the speaker wiring configuration is correct.
 Ensure the nominal page line level is correct.
 Replace the speaker or driver.

Page/Party

®

operation does not
function.

 Refer to the ADVANCE System Programming manual, Pub. 42004-700L2,

to ensure station address matches ADVANCE configuration.

 Refer to “Setting the Address” on page 13.
 Check cable connection at P4.
 Check proper cable terminations between Termination and Main PCBAs.
 Ensure proper termination on Page/Party

®

lines.

RTU output is not
functional.

 Refer to the ADVANCE System Programming manual, Pub. 42004-700L2,

for station configuration.

 For supervised output, ensure no monitored output faults exist.
 Check fuse F1 on RTU PCBA.
 Check the cable connection at P5 on the RTU and SmartSeries PCBA.
 Check RTU terminal connections on TB6 and TB7. Refer to Figure 15 and

Figure 16.

 Check operation of connected device.

RTU input does
not function.

 Refer to the ADVANCE System Programming manual, Pub. 42004-700L2,

for station configuration.

 For supervised input, ensure no monitored input faults exist.
 Check the cable connection at P5 on the RTU and SmartSeries PCBA.
 Check RTU terminal connections on TB6. Refer to Figure 17.
 Check operation of connected device.